Development of High Ambient Condensing Unit for Bulk Milk Cooling Application
Problem
Pull down time increases 4 to 4:30 hrs due to high ambient against 3 Hrs
Milk quality deteriorate by the time it reaches processing center
Current Practice
Existing BMC designed for 43 C ambient with suitable condensing units
Solution
Dairy approached Danfoss with above issue and Danfoss team in tandem with Fx Multitech developed High ambient Condensing units within required time frame
Advantage
Pull Down achieved of 3 Hrs at 48 C ambient
At lower ambient pull down is further reduced below 2.5 Hrs
Condenser fan switch provided to save energy at lower ambient
Heat Recovery valves provided which saves further 23% power and pull down to 2 Hrs at 43 C amb
Product Used
Fx assembled Condensing unit
Scroll Compressor: MLZ058
Danfoss Line Components: Filter Drier, Sight Glass, Solenoid Valves, Globe Valves, Non Return Valves.